3p 4p DC MCCB Moulded Case Circuit Breaker 1500V

Product Details
Customization: Available
Structure: MCCB
Type: Circuit Breaker
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2005

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
41
Year of Establishment
2014-03-26
  • 3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
  • 3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
  • 3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
  • 3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
  • 3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
  • 3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
Find Similar Products

Basic Info.

Model NO.
KYM3D-250
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CCC
Rated Insulation Voltage Ui(V)
1600
Rated Impulse Withstand Voltage Uimp(Kv)
12
OEM
Yes
ODM
Yes
Product Name
DC MCCB
Rated Insulation Voltage
1500V
Material
High Standard Plastic Copper and Silver
Certificate
Ce/ISO9001
Transport Package
Standard Carton
Trademark
KAYAL
Origin
China
HS Code
1904031930
Production Capacity
10000/Month

Product Description

3p 4p DC MCCB Moulded Case Circuit Breaker 1500V

DC system-specific circuit breakers are used in rated insulation voltage of 1600V and a rated operating voltage of DC1500V and below, and rated operating currents of 250A and below. C ircuit breakers are mainly used for overload and short circuit protection of distributed power and protection circuits and power equipment in DC systems . U nder normal circumstances can be used as a line of infrequent conversion and DC motor infrequent start.

1.Normal conditions of use

Ambient air temperature does not exceed the upper limit of +70ºC, the lower limit of not less than -40ºC , 24-hour average does not exceed +35ºC. (Note: Circuit breakers for use in ambient air temperatures above + 70ºC or below -40ºC should be consulted with the manufacturer);
The installation site of the altitude does not exceed 2000m (2000m above the need for the corresponding derating)
The relative temperature of the atmosphere is not more than 50% at the highest temperature around +40ºC, and can be compared at a lower temperature.High relative humidity (for example, 90% at 20ºC), and the consideration of temperature change on the surface of the product dew.
2.Normal installation conditions
Installation conditions: the general should be vertical installation or horizontal installation;
Installation categories: Class III of circuit breaker main circuit, control circuit and auxiliary circuit are class II.
Pollution level: Three
3.Normal storage and transport conditions
The temperature limit is not lower than -40ºC,the upper limit does not exceed +70ºC Relative humidity (25ºC) does not exceed 95ºC;
The product should be lightly moved during transport,should not be reversed should be acoided violent collision Main technical parameters

Main technical parameters 

Frame level 250A Rated working voltage DC500V/DC1000V DC1250V/DC1500V
Rated working current(A) 100/125/140/160
/180/200/225/250
Rated insulation voltage DC160
Pole number 2 Arcing distance ≤50mm
Breaking capacity Icu=Ics=15kA Mechanical life 200
Short circuit 
instantaneous setting
5~10 Degree of protection Ip20
Standard rule GB14048.2 IEC60947

Description of protection

Overload long delay protection

Ambient temperature Test current Appointment time Starting state
+50ºC±2ºC 1.05In ≥No action Cold state
1.3In <2h action Hot state

Short-circuit transient protection

Ambient temperature Test current Appointment time Starting state

+10ºC~+40ºC

4In or 8In ≥200ms No action
6In or 12In <200ms action

Derated coefficient when ambient temperature changes

Ambient temperature 40ºC 45ºC 50ºC 55ºC 60ºC 65ºC
Derated coefficient 1In 0.97In 0.93In 0.89In 0.85In 0.82In

A comparative relationship between the rated current of a circuit breaker and the cross section of a linked wire

Rated current 100A 125A 140A 160A 180A 200A 225A 250A
Cable intercepting area 35mm² 50mm² 70mm² 95mm² 120mm²

.High altitude derated coefficient

Altitude 2000m 3000m 4000m 5000m
Operating voltage derating coefficient 1 0.9 0.8 0.7
Operating current derating coefficient 1 0.96 0.93 0.9

3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
3p 4p DC MCCB Moulded Case Circuit Breaker 1500V

3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
3p 4p DC MCCB Moulded Case Circuit Breaker 1500V
3p 4p DC MCCB Moulded Case Circuit Breaker 1500V

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier