High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MPCB
Samples:
US$ 3.3/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2005

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GV2Overload protection electronic single phase mot
Poles Number
3/4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, UL, CCC
Rated Frequency
50/60 Hz
Certificate
TUV
Mechanical Life
20000 Operations
Application
Short-Circuit Protection
Standard
IEC60947-2
Rated Current
0.1-80A
Rated Voltage
660V
Transport Package
Export Standard Package or According to Customer′s
Trademark
KAYAL
Origin
China
HS Code
1903301924
Production Capacity
300000pieces/Month

Product Description

 High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector

High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector
High Electrical Performance Short-Circuit Breaker Gv2 Motor ProtectorAPPLICATION
GV series motor protection circuit breakers are mainly used for the overload and short circuit protection of the motor in AC 50/60HZ,up to 660V,0.1-80A power circuit,as a full voltage starter to start and cut off the motor,under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network.
SPECIFICATIONS

Type Rated standard power of 3-phase motors 50/60HZ in category AC-3 Setting range(A)
220V 380V 415V 440V 500V 660V
KW KW KW KW KW KW
GV2-M01 -- -- -- -- -- -- 0.1-0.16
GV2-M02 -- -- -- -- -- -- 0.16-0.25
GV2-M03 -- -- -- -- -- -- 0.25-0.4
GV2-M04 -- -- -- -- -- 0.37 0.4-0.63
GV2-M05 -- -- -- 0.37 0.37 0.55 0.63-1.0
GV2-M06 -- 0.37 -- 0.55 0.75 1.1 1.0-1.6
GV2-M07 0.37 0.75 0.75 1.1 1.1 1.5 1.6-2.5
GV2-M08 0.75 1.5 1.5 1.5 2.2 3 2.5-4.0
GV2-M10 1.1 2.2 2.2 3 3.7 4 4-6.3
GV2-M14 2.2 4 4 4 5.5 7.5 6.0-10.0
GV2-M16 3 5.5 5.5 7.5 7.5 9 9.0-14.0
GV2-M20 4 7.5 9 9 9 11 13.0-18.0
GV2-M21 5.5 11 11 11 11 15 17.0-23.0
GV2-M22 5.5 11 11 11 15 18.5 20.0-25.0
GV2-M32 7.5 15 15 15 18.5 26 24.0-32.0
GV3-M06 -- 0.37 -- 0.55 0.75 1.1 1.0-1.6
GV3-M07 0.37 0.75 1.1 1.1 1.1 1.5 1.6-2.5
GV3-M08 0.75 1.5 1.5 1.5 2.2 3 2.5-4.0
GV3-M10 1.1 2.2 2.2 3 3.7 4 4.0-6.0
GV3-M14 2.2 4 4 4 5.5 7.5 6.0-10.0
GV3-M20 4 7.5 7.5 7.5 10 11 10.0-16.0
GV3-M25 5.5 11 11 11 15 18.5 16.0-25.0
GV3-M40 11 18.5 22 22 25 33 25.0-40.0
GV3-M63 15 30 33 33 40 55 40.0-63.0
GV3-M80 22 40 45 45 55 63 56.0-80.0

High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector
High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector
High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector
High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector
High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector
High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector
High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector
High Electrical Performance Short-Circuit Breaker Gv2 Motor Protector
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now