0.40-0.63A Silver Point Thermal Overload Relay

Product Details
Customization: Available
Usage: Thermal Relay
Phase: 3
Still deciding? Get samples of US$ 10/Piece
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2005

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
41
Year of Establishment
2014-03-26
  • 0.40-0.63A Silver Point Thermal Overload Relay
  • 0.40-0.63A Silver Point Thermal Overload Relay
  • 0.40-0.63A Silver Point Thermal Overload Relay
  • 0.40-0.63A Silver Point Thermal Overload Relay
  • 0.40-0.63A Silver Point Thermal Overload Relay
Find Similar Products

Basic Info.

Model NO.
LRD
Electricity Type
Dc
Number of Pole
3
Load
Weak Power Relay
Protective Characteristics
Sealed Relay
Action Principle
Thermal Relay
Size
Miniature
Type
Electric Parameter Relay
Product Name
24 Volt DC Relay
Certificate
Ce/CB
Voltage
230/240V Upto 660V
Current
0.1-93A
Frequency
50Hz / 60Hz
Materials
PA/Materials
Rated Working Current
25 36 93A Seperately
Transport Package
Carton
Trademark
KAYAL
Origin
China
HS Code
1904021928
Production Capacity
350000pieces/Month

Product Description

 0.40-0.63A Silver Point Thermal Overload Relay

0.40-0.63A Silver Point Thermal Overload Relay
0.40-0.63A Silver Point Thermal Overload Relay
Excellent Material Good Quality contactor industrial,contactor 110v dc 100 amp

APPLICATION 

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------

This series of thermal relay can be used in the circuit of 50Hz or 60Hz,rated insulation voltage 660V,rated current 0.1-96A for protecting the phase break when the electric motor is overload. The relay has different mechanism and temperature compensation & can be plugged in LC1-D series AC contactor.It is the most advanced thermal relay in the nineties in the world.

CHARACTERISTICE 

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------

      A.Fundamental parameter of the main circuit
(a).Rated insulation voltage 660V.
(b).Rated working current 25,36,93A separately.
(c).The regulator seal of rated setting current and setting.
(d).Current of the thermal component(see list 1)

      B.Auxiliary Circuit
(a).There is one pair of NO/ and N/C contact with electric insulation.
(b).Rated insulation voltage 500V.
(c).Rated frequency 50-60Hz.
(d).Use group, rated working voltage ,appoint thermal current and rated  current.

Motion Characteristic: Three-phase Balance Motion Time

 

No Times of the setting current Motion time Start condition Ambient temperature
1 1.05 >2h Cold state 20±5oC
2 1.2 <2h Heat state(Following the No.1 test)
3 1.5 <4min
4 7.2 10A 2s< Tp≤10s ≤63A Cold state
10 4s< Tp≤10s >63A

Phase-losing Motion Characteristic

No Times of the setting current Motion time Start condition Ambienttemperature
Any two phases Another phase
1 1.0 0.9 >2h Cold state 20±5oC
2 1.15 0 <2h Heat state(Following the No.1 test)

 

SPECTFICATION

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Type Number Setting range (A) For contactor
LR2-D13 1301 0.1~0.16 CJX2-09~32
1302 0.16~0.25 CJX2-09~32
1303 0.25~0.4 CJX2-09~32
1304 0.4~0.63 CJX2-09~32
1305 0.63~1 CJX2-09~32
1306 1~1.6 CJX2-09~32
1307 1.6~2.5 CJX2-09~32
1308 2.5~4 CJX2-09~32
1310 4~6 CJX2-09~32
1312 5.5~8 CJX2-09~32
1314 7~10 CJX2-09~32
1316 9~13 CJX2-09~32
1321 12~18 CJX2-09~32
1322 17~25 CJX2-32
LR2-D25 2353 23~32 CJX2-09~32
2355 30~40 CJX2-09~32
LR2-D33 3322 17~25 CJX2-09~32
3353 23~32 CJX2-09~32
3355 30~40 CJX2-09~32
3357 37~50 CJX2-09~32
3359 48~65 CJX2-09~32
3361 55~70 CJX2-09~32
3363 63~80 CJX2-09~32
3365 80~93 CJX2-95
LR2-D43 4365 80~104 CJX2-95
4367 95~120 CJX2-95~115
4369 110~140 CJX2-115

 

Type Rated working current of thermal relay Thermal component
Rated current(A)

Rated or scale of 

rated current (A)

LR2-D13 25 LR2-D1301 0.16 0.10-0.16
LR2-D1302 0.25 0.16-0.25
LR2-D1303 0.4 0.25-0.40
LR2-D1304 0.63 0.40-0.63
LR2-D1305 1 0.63-1.0
LR2-D1306 1.6 1.0-1.6
LR2-D13x6 2 1.25-2.0
LR2-D1307 2.5 1.6-2.5
LR2-D1308 4 2.5-4.0
LR2-D1310 6 4.0-6.0
LR2-D1312 8 5.5-8.0
LR2-D1314 10 7.0-10.0
LR2-D1316 13 9.0-13.0
LR2-D1321 18 12.0-18.0
LR2-D1322 25 17.0-25.0
LR2-D23 36 LR2-D2353 32 23.0-32.0
LR2-D2355 36 28.0-36.0
LR2-D33 93 LR2-D3353 32 23.0-32.0
LR2-D3355 40 30.0-40.0
LR2-D3357 50 37.0-50.0
LR2-D3359 65 48.0-65.0
LR2-D3361 70 55.0-70.0
LR2-D3363 90 63.0-80.0
LR2-D3365 93 80.0-93.0

0.40-0.63A Silver Point Thermal Overload Relay
0.40-0.63A Silver Point Thermal Overload Relay
0.40-0.63A Silver Point Thermal Overload Relay
0.40-0.63A Silver Point Thermal Overload Relay
0.40-0.63A Silver Point Thermal Overload Relay
0.40-0.63A Silver Point Thermal Overload Relay
0.40-0.63A Silver Point Thermal Overload Relay
0.40-0.63A Silver Point Thermal Overload Relay
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier